HZYN-1301 ASTM D445 Automatisk oljekinematisk viskosimeter
HZYN-1301 kinematisk viskositet Bath Astm D445 oljekinematisk viskosimeter
Översikt
This Kinematic Viscometer is designed and manufactured specially according to the national standard "GB265 – 88 Determination of kinematic viscosity of petroleum products" . It's suitable to determine kinematic viscosity of liquid petroleum products. This apparatus has the function of timing of the trial sample movement and can calculate the final result of kinematic viscosity. This method is suitable to determine kinematic viscosity of liquid petroleum products ( It refers to Newtonian liquids ), and its unit is m2/s. Generally in actual utilization, the unit is mm2/s. The dynamic viscosity is equal with the result which use kinematic viscosity to multiply the density of the liquid. By this method, it can determine the time that the liquid with the certain volume flows past the calibrated glass capillary viscometer under the gravity in the certain stable temperature and the value that the constant value of capillary in the viscometer multiplies the flowing time, that is , the determined kinematic viscosity of liquid at the temperature. At the temperature, the value that kinematic viscosity multiplies the density of the liquid in the same temperature is the dynamic viscosity at the temperature.

Tekniska data
Flytande badhål | 4 |
Område för att kontrollera temperaturen | Indoor temperature—120 degree |
Precision för att kontrollera temperaturen | Room temperature -120 degree Less than or equal to ±0.1 degree |
Rumstemperatur | -40 degree Less than or equal to ±0.2 degree |
Ingångsströmkälla | AC220V±10V, 50HZ |
Värmekraft | 1000W |
Testtider | Från 1 till 6 gånger, kan justeras. |





Användningsvillkor
(1) Omgivningstemperatur: 0 grader -40 grader
(2) Relativ luftfuktighet:<>
Uppmärksamhet
(1). När det inte finns något vatten inne i akvariet, förbjuder det strömmen.
(2). In the liquid of the bathtub, there can't be impurities and floating materials in order to avoid to block the test holes. For the new bath liquid , it often appears bubbles when heating, which will affect the test, especially when it appears bubbles in the test holes, it will have the most serious affect. Please loose the capillary to check if there is bubble in the test holes. If it appears, please use the hose to blow in order to get rid of the bubbles or use the clean the toothbrush to wash off the bubbles.
(3). Innan vi använder apparaten måste vi säkerställa tillförlitlig jordning.
(4). När vi-startar om apparaten måste användningsintervallet vara över 15 minuter. Och apparaten startas i kallbadtillståndet och måste användas efter 45 minuter.
(5). When we rectify the temperature with the full-immersion thermometer, the effective scale of the thermometer can't be exposed to the liquid level of the constant temperature bath.
(6). Förbjud att förvara eller använda apparaten i den våta miljön med den frätande gasen.
(7). När vi klipper kapillären, notera höjden på den övre öppningen och undvik att komma in i vatten i provröret.
(8). Efter användning under en period eller när vi finner att oljenivåmätningen är okänslig bör vi rengöra testhålen i testklämman i tid.
(9). During using the apparatus, if appears fault, you should invite the professionals to repair and contact with us in time. If it's quality problem, we can offer the gratuitous warranty within one year.
(10). För strömkällan måste du behålla den goda jordningen.



Populära Taggar: HZYN-1301 ASTM D445 Automatisk oljekinematisk viskosimeter, Kina, leverantörer, tillverkare, pris, till salu, kinematisk viskosimeter, kinematisk viskosimeter för petroleumprodukter, automatisk bärbar kinematisk viskosimeter, kinematisk viskosimeterbad, kinematisk viskosimeter med digitalt bad, ISO3104 Crude Viscometer , hzyn-1301, kinetisk viskositetsmätare, kinematisk viskositetstest av bitumen, kinematisk viskositetsmätare för isoleringsolja, kinematisk viskositetsmätare, motoroljas viskositetsmätare