When it is interfered or contaminated, grid power quality can't reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country.
Tekniska specifikationer
Projekt | Data | |
Antal mätkanaler | Fyra spänningskanaler, fyra strömkanaler | |
Mätområde | Spänning | 0-900V |
Nuvarande | Liten klämma: diameter 8 mm, 5A/25A (standard) Medium klämma: diameter 50 mm, 100A/500A (valfritt) Stor klämma: diameter 12550mm, 400A/2000A (valfritt) | |
Fasvinkel | 0.000-359.999 degree | |
Frekvens | 42.5-69Hz | |
Mätsteg | Spänning | 0.001V |
Nuvarande | 0.0001A | |
Fasvinkel | 0.001 grad | |
Kraft | aktiv effekt {{0}}.01W,reaktiv effekt 0.01Var | |
Frekvens | 0.0001Hz | |
Spänningsmätningsnoggrannhet | Mindre än eller lika med 0,1 procent | |
Strömmätningsnoggrannhet | Mindre än eller lika med 0,3 procent | |
Noggrannhet för mätning av fasvinkel | Mindre än eller lika med 0,1 grad | |
Power measurement accuracy | Mindre än eller lika med 0,5 procent | |
Frequency measurement accuracy | Mindre än eller lika med 0.01Hz | |
Harmoniska analystider | 2-64 times | |
Harmonisk spänningsmätningsfel | Harmonic content>1 percent Nominal value: Less than or equal to 1 percent RD Harmonic content<1 percent Nominal value: Less than or equal to 0.05 percent FS | |
Harmonisk strömmätningsfel | Harmonic content>3 percent Nominal value: Less than or equal to 1 percent RD Harmonic content<3 percent Nominal value: Less than or equal to 0.05 percent FS | |
Trefas spänningsobalansfel | Mindre än eller lika med 0,2 procent | |
Trefas strömobalansfel | Mindre än eller lika med 0,5 procent | |
Spänningsfluktuationsnoggrannhet | 5 procent | |
PST-mätningstid | 10 minuter | |
PLT-mätningstid | 2h | |
PST/PLT-mätfel | Mindre än eller lika med 5 procent | |
Skärm | 1280800,Äkta färg LCD | |
Laddningskraft | AC220V±15 percent Frekvens 45Hz-65Hz | |
Standby timing | Större än eller lika med 10h | |
Värdkraft | <4VA | |
Isolering | 1) The insulation resistance between the voltage, current input terminal and the housing Less than or equal to 100MΩ. 2) Tål 1,5KV (giltigt värde) med strömfrekvens på drifteffekt och skalet, som varar en minut. | |